- Additional Product Details
Heavy Duty Rim Exit Device - (versions suit doors <915mm & 1220mm)
Per BS EN 1125: 2008 Annexe A (informative), the device should be installed with the touch bar typically between 900mm and 1100mm from the finished floor level when the door is secure. Where it is known that most of the premises' occupants will be young children, it is acceptable to reduce the fixing height accordingly.
- Device functions - Ships ready for all functions: DT, EO, L, NL, NL-OP & TP
- Universal - Non-handed, suits LH & RH doors
- Device lengths - Devices suit door widths to 915mm; optional devices suit doors to 1220mm
- Optional finish - SP313 (695) Sprayed Dark Bronze
- Strikes - Ships with standard 299 roller strike; optional strikes are available to suit alternative frame details. 299 standard roller strike with 21mm projection, used with conventional frames where the door stile width (>121mm) permits the necessary backset. 1609 optional strike used on doors with flush frames or fixed to the inactive (or first closing) leaf of a rebated pair of doors.
- Dogging feature - Hex key dogging keeps the latch bolt held back for free swinging operation; LD less dogging is available to special order
- Fasteners - Includes fixings for both metal and timber doors from 19mm - 57mm thick with sex bolts available to special order - 425 for bolt-through fixings
- Latch Bolt - Easy action friction-free deadlocking latches cannot be depressed from the outside - 19mm throw
Selected Electrified Options -LX Latchbolt Monitor Switch
RX Touch Bar Monitor Switch
RX2 Double Touch Bar Monitor Switch (RX2 feature uses two RX switches)
ALK Alarm Exit KitOptional Trim (for Outside Access) add suffix -
DT - Dummy Trim (210)
EO - Exit Only
L - Lever (230)
NL - Night Latch (210)
NL - Night Latch w. Pull (230)
NL-OP - Rim Cylinder - Optional Pull Required (20-022)
TP - Thumb Piece (230)Designed specifically for use in areas where frequent abusive treatment can be expected, the 22 series is constructed from a heavy gauge rolled steel section and has the proven heavy-duty touch bar mechanism that has been used so successfully in all architectural-grade Von Duprin touch bar devices. It is best suited to heavy-duty situations on perimeter and internal doors where safe egress in panic emergencies is required.
LCN Door Closers | Von Duprin Exit Devices | Schlage Locks
Relcross Limited (trading as) Relcross Door Controls | Hambleton Avenue | DEVIZES | Wiltshire | SN10 2RT | United Kingdom | T: ++ 44 (0) 1380 729 600 | F: ++ 44 (0) 1380 729 888 | E: sales@relcross.co.uk
- Certification
UK Fire Certification per BS EN 1634-1:2014+A1:2018 (timber) - 120 mins (the addition of an outside access device restricts the fire certification to 60 minutes)
WFRC No. C132276EN 1125: 2008
UKCA | CE | ANSI | UL* | 120 Mins Timber | Warranty: 3 Years (Mechanical)
*UL Listing for Fire Exit Hardware (add Suffix -F)
Certificates, including DoPs, downloadable here
- Resources | Downloads