- Additional Product DetailsRamp thresholds are often used to allow safe movement (most often via wheelchair access) between offset floor conditions. These shapes are designed to meet accessibility requirements.
- Ramp assemblies comprise interlocking components, eliminating the need to weld joints. These assemblies can be configured to accommodate changes in floor conditions from 13mm to 57mm
- Assemblies accommodate 13mm to 57mm floor offsets in meeting the 1:12 slope requirements of the ADA in North America and the Equality Act 2010 in the United Kingdom. Higher offsets can be accommodated by using the risers RAMP13_ and RAMP14_
- We recommend our specially designed Mitre Returns.
- MR in a product number denotes that one pair (or set) of mitre returns (and mitre return extenders, if applicable) are included. Otherwise, we recommend filling and feathering the threshold ends with grout. Do not leave threshold ends open. - Mitre Returns are available for offsets up to 57mm
- Assemblies are supplied with #10 stainless steel wood screws. Stainless steel machine screws and expansion shields are available at an extra cost. Assemblies allow for custom fabrication (i.e. notching, side access extensions, etc.); please consult relcross door controls
- Assemblies are provided NET length.
38.1mm Floor Offset
R1.5F_ & R1.5FMR_ **
AVAILABLE FINISHES: A, AK44mm Floor Offset
R1.75F_ & R1.75FMR_ **
AVAILABLE FINISHES: A, AKFinishes
A (Mill Finish Aluminium) AK (Mill Finish Aluminium with Pemkote™ Non-Slip Coating)
The term ‘Access’ generally means the ease with which users can enter and circulate a building, with regard to other performance requirements, e.g. security and fire protection. In particular, access should be provided for both ambulant and wheelchair-bound persons.
We offer a wide range of saddles, thresholds and ramps that satisfy the requirements of Document 'M’. Designers should refer to BS 8300:2009+A1:2010 Design of buildings and their approaches to meet the needs of disabled people. Code of practice and Approved Document M - Access to & Use of Buildings 2004, incorporating Revisions 2010 & 2013.
Ramp options include modular systems that can be assembled to suit virtually any ramp length. Our 'Fire Retardant Rubber Ramp System' incorporates anti-slip features to satisfy the demanding Underwriters Laboratories safety standard UL410 and meets the requirements of US standards ASTM D 2047 and Federal Specification P-F-430C.Doors are typically the weakest link in any partition designed to have acoustic sealing properties. Astragals, perimeter gasketing, drop seals, and door sweeps can all prevent sound from leaking through cracks around the door perimeter.
LCN Door Closers | Von Duprin Exit Devices | Schlage Locks
Relcross Limited (trading as) Relcross Door Controls | Hambleton Avenue | DEVIZES | Wiltshire | SN10 2RT | United Kingdom | T: ++ 44 (0) 1380 729 600 | F: ++ 44 (0) 1380 729 888 | E: sales@relcross.co.uk
- Certification
UL | Warranty: 5 Years (Mechanical)
Certificates, including DoPs, downloadable here
- Resources | Downloads