LCN 1000 series closers feature a modern slim line design for easy installation
on narrow head frames and top rails.
Applications
- For aluminium, hollow metal and timber (butt hung or pivoted) single
action doors
- 1000 series closers will fit transoms as narrow as 44mm without the
need for adaptor (drop) plates.
- Adaptor plates and accessories are available for unusual conditions
- For closers from this range offering possible compliance with DDA
please refer to DDA
Compliance - Fire Doors
Features common to the 1000 series:
- Fully universal. Closers from Relcross always include the parallel
arm (designated suffix -P) 62 PA shoe.
- Regular or (optional) hold open arms mount hinge side or top jamb
and are available mounts with the 'P' version.
- All closers are non-handed and fit left hand and right hand doors.
- All conventional applications have a 'size one' setting (spring strength)
indicated by the suffix -1 (e.g. 1461 and 1071).
- Adjustable hydraulic backcheck cushions the opening arc prior to 90
degrees.
- Separate regulation of closing and latching speeds.
- Ball joints in regular arms and shoes to accommodate uneven trim.
- Reversible shoe to boost latching power on double lever arms.
Warranty
- 10 year limited warranty. See terms and conditions and standard Warranty
Document for more information
Materials
- High strength cast iron cylinder
- Forged steel main arms
- One piece forged steel pistons
- Heat treated pinion
- All weather fluid eliminates seasonal adjustment. Temperature
range 49 deg. C to minus 35 degrees C
- High efficiency, full compliment, low friction bearings
- Tamper resistant regulating screws
- Full rack and pinion hydraulic action
- Quiet, low friction track and roller combination for all single
lever arm closers
Finishes
- Available from stock in US28 silver powder coated finish
- Available in wide range of powder coated finishes to match any RAL
colour (to special order)
- LCN's powder coated finish surpasses 100 hours of salt spray - four
times the ANSI (US) standard.
- See also BS EN certification for more information on salt spray testing
Maintenance
- Closers mounted in accordance with LCN installation instructions require
no periodic maintenance or adjustment
|